Transmission Hardware Corona Performance and HVDC Submarine Cable EM Fields

Дата публикации: 30-04-2026 10:00:01


Laboratory or in-field measurements are often considered the gold standard for certain aspects of power system design; however, measurement approaches always have limitations. Simulation can help overcome some of these limitations, including speeding up the design process, reducing design costs, and assessing situations that are often not feasible to measure directly. In this presentation, we will discuss two examples from the power system industry. The first case we will discuss involves corona performance testing of high-voltage transmission line hardware. Corona-free insulator hardware performance is critical for operation of transmission lines, particularly at 500 kV, 765 kV, or higher voltages. Laboratory mockups are commonly used to prove corona performance, but physical space constraints usually restrict testing to a partial single-phase setup. This requires establishing equivalence between the laboratory setup and real-world three-phase conditions. In practice, this can be difficult to do, but modern simulation capabilities can help. The second case involves submarine HVDC cables, which are commonly used for offshore wind interconnects. HVDC cables are often considered to be environmentally inert from an external electric field perspective (i.e., electric fields are contained in the cable, and the cable’s static magnetic fields induce no voltages externally). However, simulation demonstrates that ocean currents moving through the static magnetic field satisfy the relative motion requirement of Faraday’s law. Thus, externally induced electric fields can exist around the cable and are within a range detectable by various aquatic species.Key Takeaway: Learn how to use modern simulation to translate single-phase laboratory corona mockups into accurate three-phase real-world performance for 500 kV and 765 kV systems.Explore the physics behind how ocean currents interacting with HVDC submarine cables create induced electric fields—a phenomenon often overlooked but detectable by aquatic species.Gain actionable insights into how to leverage simulation to reduce design costs and bypass the physical space constraints that often stall traditional testing.See a practical application of electromagnetic theory as we demonstrate how relative motion in static magnetic fields necessitates simulation where direct measurement is unfeasible.Register now for this free webinar!

Основное содержимое страницы с новостью.

On-Demand

Laboratory or in-field measurements are often considered the gold standard for certain aspects of power system design; however, measurement approaches always have limitations.  Simulation can help overcome some of these limitations, including speeding up the design process, reducing design costs, and assessing situations that are often not feasible to measure directly. In this presentation, we will discuss two examples from the power system industry. 

The first case we will discuss involves corona performance testing of high-voltage transmission line hardware. Corona-free insulator hardware performance is critical for operation of transmission lines, particularly at 500 kV, 765 kV, or higher voltages. Laboratory mockups are commonly used to prove corona performance, but physical space constraints usually restrict testing to a partial single-phase setup. This requires establishing equivalence between the laboratory setup and real-world three-phase conditions. In practice, this can be difficult to do, but modern simulation capabilities can help.   The second case involves submarine HVDC cables, which are commonly used for offshore wind interconnects. HVDC cables are often considered to be environmentally inert from an external electric field perspective (i.e., electric fields are contained in the cable, and the cable’s static magnetic fields induce no voltages externally). However, simulation demonstrates that ocean currents moving through the static magnetic field satisfy the relative motion requirement of Faraday’s law. Thus, externally induced electric fields can exist around the cable and are within a range detectable by various aquatic species.

Key Takeaway: 

  •  Learn how to use modern simulation to translate single-phase laboratory corona mockups into accurate three-phase real-world performance for 500 kV and 765 kV systems.
  • Explore the physics behind how ocean currents interacting with HVDC submarine cables create induced electric fields—a phenomenon often overlooked but detectable by aquatic species.
  • Gain actionable insights into how to leverage simulation to reduce design costs and bypass the physical space constraints that often stall traditional testing.
  • See a practical application of electromagnetic theory as we demonstrate how relative motion in static magnetic fields necessitates simulation where direct measurement is unfeasible.

Who Should Attend:

  • Transmission engineers, submarine cable designers, and environmental compliance officers

    Can't attend live? Register for the recording.

Note that COMSOL will follow up with all registrants about this event and any related questions.

*Please see www.comsol.com/privacy for COMSOL's Privacy Policy. Contact COMSOL at www.comsol.com/contact for more information.

Схожие новости

#Наименование новостиТональностьИнформативностьДата публикации
1Modeling and Simulation Approaches for Modern Power System Studies011.1927-04-2026
2Practical Comparison of Electromagnetic Simulation Tools for a Terahertz Microstrip Antenna01012-05-2026
3Designing Broadband LPDA-Fed Reflector Antennas With Full-Wave EM Simulation011.7917-04-2026
4Experimental Study of a Pneumatic-Electromagnetic Linear Power Generator Based on Pneumatic Power Transmission05.8301-01-2027
5Grid Operators Weigh High-Voltage DC Power for Data Centers011.6416-07-2026
6Физики выяснили, как космическая погода влияет на рост паразитных токов ...0704-07-2026
7Simulation Analysis of Motor Cooling System for Electric Driven UAV07.1701-01-2027
8Predict Antenna Coupling on Electrically LargePlatforms Before Building Hardware017.8114-08-2026
9Проектирование внешнего электроснабжения объектов: от технических условий до стройки013.9407-04-2026
10Advancing Vehicle Crash and Safety Analysis with AI and Physics-Simulations0505-07-2026

Классификация: Пресс-релизы. Схожих патентов: 0. Схожих новостей: 10. Тональность: 0. Информативность: 8.82. Источник: spectrum.ieee.org.